Product Details:
Payment & Shipping Terms:
|
Standards: | ASTM G 153 , ASTM D 4329 | Weight: | About 150 KGS |
---|---|---|---|
Condensation Temperature: | 40 ~ 60 ℃ | Temperature Resolution: | 0.1 ℃ |
Wave Length: | 315 ~ 400 NM | Humidity Range: | 45%~70%R.H (light State) |
High Light: | uv aging test chamber,uv lamp testing equipment |
AC 220V 50Hz UV Aging Test Chamber, UV Accelerated Weathering Tester
1. Application
1.1 The UVA-340 fluorescent ultraviolet lamp is used as the light source to simulate the damage caused by sunlight, rain and dew. UV weatherproof chamber uses fluorescent ultraviolet lamp to simulate the effect of sunlight, and uses condensation moisture to simulate dew. The material under test is placed in a cyclic program of alternating light and moisture at a certain temperature. The accelerated weathering test is carried out to obtain the results of the weathering resistance of the material. UV chambers can be used for several days or weeks to reproduce the hazards of outdoor months or years. Hazard types include: fading, discoloration, loss of light, pink, cracking, turbidity, bubbles, brittleness, strength, decay and oxidation. This machine contains sprinkling device.
1.2 The ultraviolet accelerated aging test chamber can simulate the ultraviolet, rain, high temperature, high humidity, condensation, darkness and other environmental conditions in the natural climate, by reproducing these conditions, merging into a cycle, and letting it automatically complete the cycle number. This is the working principle of UV aging test chamber. In this process, the equipment can automatically monitor the blackboard temperature and the flume temperature. By configuring the irradiance measuring and controlling device (optional), the irradiance can be measured and controlled, so that the irradiance can be stabilized at 0.76W/m2/340nm or the specified set value, and the life span of the lamp can be greatly prolonged.
2. Standards
Conforms with ASTM G 153, ASTM G 154, ASTM D 4329, ASTM D 4799, ASTM D 4587, SAE J2020, ISO 4892, all current UV aging test standards.
3. Techincal Parameters
External dimension |
1300mm x 500mm x 1460mm |
Internal dimension | 1140mm x 400mm x 380mm |
Standard sample size | 75 x 150mm 48pcs |
Light temperature range | 50~70 ℃ |
Condensation temperature range | 40~60 ℃ |
Temperature tolerance | ±3 ℃ |
Temperature resolution | 0.1 ℃ |
Temperature control mode | PID self-tuning temperature control mode |
Humidity range | 45%~70% R.H (light state) |
Above 98% (condensation state) | |
Sink requirements | Water depth ≤ 25mm |
Automatic controller for water supply | |
Distance between sample and tube center | 50 mm |
Wave length range | 315~400 nm |
Radiation intensity | 1.2W / m2 / 340 nm |
Weight | 150 kgs |
Power requirements | AC 220V 50Hz, 8A, 10A slow melting fuse |
Single-phase three wires |