Product Details:
Payment & Shipping Terms:
|
Inner Size: | 1140 X 400 X 380 MM | Outline Size: | 1300 X 500 X 1460 MM |
---|---|---|---|
Sample Size: | 75 X 150 MM | Temperature Resolution: | 0.1 ℃ |
Wavelength Range: | 315 ~ 400 NM | Sample Holder Size: | 404 X 105 MM |
High Light: | uv aging test chamber,uv lamp testing equipment |
Box-type UV Aging Test Chamber / UV Simulation Environment Test Chamber
1. Application
1.1 The UVA-340 fluorescent ultraviolet lamp is used as the light source to simulate the damage caused by sunlight, rain and dew. UV weatherproof chamber uses fluorescent ultraviolet lamp to simulate the effect of sunlight, and uses condensation moisture to simulate dew. The material under test is placed in a cyclic program of alternating light and moisture at a certain temperature. The accelerated weathering test is carried out to obtain the results of the weathering resistance of the material. UV chambers can be used for several days or weeks to reproduce the hazards of outdoor months or years. Hazard types include: fading, discoloration, loss of light, pink, cracking, turbidity, bubbles, brittleness, strength, decay and oxidation. This machine contains sprinkling device.
1.2 The ultraviolet accelerated aging test chamber can simulate the ultraviolet, rain, high temperature, high humidity, condensation, darkness and other environmental conditions in the natural climate, by reproducing these conditions, merging into a cycle, and letting it automatically complete the cycle number. This is the working principle of UV aging test chamber. In this process, the equipment can automatically monitor the blackboard temperature and the flume temperature. By configuring the irradiance measuring and controlling device (optional), the irradiance can be measured and controlled, so that the irradiance can be stabilized at 0.76W/m2/340nm or the specified set value, and the life span of the lamp can be greatly prolonged.
2. Standards
Conforms with ASTM G 153, ASTM G 154, ASTM D 4329, ASTM D 4799, ASTM D 4587, SAE J2020, ISO 4892, all current UV aging test standards.
3. Main technical parameters
3.1 The center distance of the lamp: 70mm
3.2 The nearest parallel surface distance between the specimen and the lamp surface: About 50mm
3.3 Wave length range: UV-A wave length range is 315 ~ 400nm
3.4 Radiation intensity: 1.2W / m2 / 340nm
3.5 Temperature resolution: 0.1 ℃
3.6 Light temperature range: 50 ~ 70 ℃ / temperature tolerance is ± 3 ℃.
3.7 Condensation temperature range: 40 ~ 60 ℃ / temperature tolerance is ± 3 ℃.
3.8 Temperature control mode: PID self-tuning temperature control mode.
3.9 Humidity range: about 45% ~ 70% R.H (light state) / 98% above (condensation state)
3.10 Sink requirements: water depth is not greater than 25mm, and there is automatic controller for water supply.
3.11 Standard sample size: 75 x 150mm 48pcs
3.12 Internal dimensions: 1140mm x 400mm x 380mm
3.13 External dimensions: 1300mm x 500mm x 1460mm
3.14 Weight: about 150 kgs
3.15 Power requirements: 220V ± 5%, single-phase three wires, 50Hz, 8A, 10A slow melting fuse.